mcp server
engineering
27 engineering compliance and calculation tools for the built environment (UK, EU, UAE).
Description as published by the maintainer. Source
- version 1.0.0
- active
- security
active — Registry entry last updated 2026-07-26. Dashed tags are derived by ZBS Index from the published description, not stated by the maintainer.
What this server can do
27 functions, named and described by the server itself. Parameter names are shown because they say more about what a function does than its name usually does.
assess_epbd_score(country, year_built, current_epc, has_solar_pv, building_type, floor_area_m2, heating_system)- Assess EU EPBD (2024) compliance. Returns compliance score, renovation cost estimate, deadline pressure, and priority retrofit measures. Required: building_type, year_built, current_epc, heating_system, has_solar_pv, floor_area_m2, country.
building_carbon_footprint(location, occupancy, year_built, refrigerant, gas_kwh_year, building_type, elec_kwh_year, floor_area_m2, heat_kwh_year, renewable_pct)- Building carbon footprint (Scope 1/2/3) with CRREM stranding check and embodied carbon. Returns per-scope tCO2e, intensity, CRREM compliance, net-zero gap and priority actions. Required: building_type, floor_area_m2, location, year_built.
building_readiness(bim, floors, location, condition, structure, year_built, current_use, proposed_use)- Building Readiness assessment for change-of-use / conversion. Returns a 0-100 readiness score, project complexity, four domain scores (structural, MEP, compliance, digital/BIM) with RAG, and recommendations. Required: current_use, proposed_use, year_built, structure, floors, condition, location, bim.
calculate_carbon(country, building_type, floor_area_m2, energy_kwh_year, construction_year)- Calculate operational + embodied carbon and net-zero gap (CIBSE TM65 / RICS WLCA). Returns carbon intensity, benchmark, and prioritised reduction measures with payback. Required: floor_area_m2, building_type, country.
calculate_pue(cooling_kw, it_load_kw, lighting_kw, ups_losses_kw)- Calculate Power Usage Effectiveness (PUE) for a data centre or server room. Returns PUE score, efficiency rating, annual cost estimate, and engineering recommendations. Required: it_load_kw, cooling_kw, ups_losses_kw, lighting_kw.
check_grid_feasibility_uae(intended_use, site_location, voltage_level, has_existing_supply, power_requirement_mw, target_completion_year)- Assess UAE grid connection feasibility (DEWA/ADDC/SEWA/FEWA). Returns feasibility score, connection timeline, recommended voltage, substation requirement, and next steps. Required: site_location, power_requirement_mw, voltage_level, intended_use, has_existing_supply, target_completion_year.
check_nis2_readiness(sector, has_ciso, has_ir_plan, has_ot_policy, has_24h_reporting, has_ot_monitoring, organisation_size, has_asset_inventory, has_board_reporting, has_supplier_assessment, has_network_segmentation)- Assess NIS2 Directive (EU 2022/2555) compliance readiness. Returns compliance score (0-18), maturity level, estimated fine exposure, and prioritised remediation actions. Required: has_ciso, has_ot_policy, has_board_reporting, has_asset_inventory, has_network_segmentation, has_ir_plan, has_24h_reporting, has_supplier_assessment, has_ot_monitoring, organisation_size, sector.
check_uae_bim_compliance(emirate, has_bep, ifc_export, bim_software, building_type, has_bim_model, building_floors, building_area_m2)- Check UAE BIM mandate applicability (Dubai Circular 196, Abu Dhabi DMT, Sharjah). Returns mandate status, compliance score, required LOD, and submission checklist. Required: building_area_m2, building_floors, emirate, building_type, has_bim_model, bim_software, ifc_export, has_bep.
check_uae_cybersecurity(emirate, has_isms, is_cloud_hosted, organisation_type, has_incident_response, has_third_party_audit, has_data_classification, has_vulnerability_assessment)- Assess UAE cybersecurity regulatory compliance (NESA IAS, Dubai ISR, CBUAE, TDRA). Returns applicable framework, compliance score, critical gaps, and mandatory controls. Required: organisation_type, emirate, has_isms, has_incident_response, has_vulnerability_assessment, has_third_party_audit, has_data_classification, is_cloud_hosted.
contractor_vetting(answers, purpose)- NIS2 / EPBD contractor vetting score from a 12-question checklist across financial, technical, cyber (NIS2) and energy (EPBD) categories. Flags blocking (critical) failures and returns recommended additional checks. Not a formal due-diligence report. Required: answers.
dgnb_bim_readiness(answers, cert_target)- DGNB certification pre-score and BIM (ISO 19650) maturity self-assessment from a 20-question checklist. Returns pre-score, achievable certification level, BIM level, domain breakdown and prioritised gaps. Not a formal DGNB audit. Required: answers.
digital_renovation_passport(era, address, country, heating, current_epc, building_type, floor_area_m2)- EPBD-style staged digital renovation passport: 3-phase roadmap (quick wins, system upgrades, deep renovation) with cost ranges, energy savings and EPC trajectory from current EPC, floor area and heating type. Indicative. Required: floor_area_m2, current_epc, heating.
eed_datacentre_pack(it_power_kw, it_energy_kwh, water_input_m3, reused_heat_kwh, total_energy_kwh, renewable_energy_kwh)- EU Energy Efficiency Directive data-centre reporting pack (Dir (EU) 2023/1791 Art.12 + Del. Reg (EU) 2024/1364). Determines reporting scope (IT power >= 500 kW) and computes the mandated KPIs PUE, WUE, ERF and REF. Note: the regulation mandates reporting, not target values. Required: it_power_kw, total_energy_kwh, it_energy_kwh.
estimate_cooling_load(it_load_kw, redundancy, space_type, climate_zone, floor_area_m2, occupancy_persons)- Estimate cooling load using CIBSE Guide B2 / ASHRAE methodology. Returns required capacity, installed capacity with redundancy, system recommendation, and annual energy. Required: space_type, floor_area_m2, it_load_kw, occupancy_persons, climate_zone, redundancy.
eu_cost_benchmarking(bim, country, programme, procurement, project_type, floor_area_m2, specification)- Parametric construction cost benchmark across UK/EU/GCC by country, project type, specification, procurement, programme and BIM. Returns per-m2 and total cost ranges plus a cost breakdown. Indicative parametric estimate, validate against current cost indices. Required: floor_area_m2, country, project_type.
eurocode_beam_designer(grade, config, span_m, exposure, material, udl_kn_m, fire_rating, load_position, point_load_kn)- Preliminary Eurocode beam design (steel EC3 / composite / reinforced concrete EC2). Selects a section, computes ULS bending & shear utilisation, SLS deflection, and fire protection. Indicative, not a stamped design. Required: material, config, span_m, udl_kn_m.
eurocode_column_checker(section, depth_mm, material, width_mm, axial_load_kn, buckling_curve, eccentricity_mm, reinforcement_pct, effective_length_m)- Eurocode axial column buckling check (steel EC3 6.3.1 flexural buckling / RC EC2 5.8 simplified). Returns Ncr, non-dimensional slenderness, reduction factor chi, NRd and utilisation. Indicative, not a stamped design. Required: axial_load_kn, effective_length_m, material.
get_technical_dd_quote(geography, disciplines, building_type, gross_area_m2, timeline_weeks, transaction_type)- Generate an indicative Technical Due Diligence (TDD) fee estimate. Returns preliminary and full DD fee ranges (GBP), turnaround days, and contact CTA. Required: building_type, gross_area_m2, transaction_type, disciplines, geography, timeline_weeks.
heatpump_heatloss(storeys, age_band, location, flow_temp_c, floor_area_m2, air_change_rate, ceiling_height_m, glazing_pct_of_floor, external_design_temp_c, internal_design_temp_c)- Domestic whole-dwelling fabric + ventilation heat-loss estimate for heat pump sizing (BS EN 12831 / MCS), from floor area, storeys, age band, location and glazing. Returns design heat loss (kW), recommended heat pump output, indicative SCOP and annual demand. Typical U-values/SCOP, not measured. Required: floor_area_m2, age_band, location.
mees_checker(property_type, current_epc_band)- England & Wales Minimum Energy Efficiency Standard (MEES) check for private rented property. Tests against the in-force EPC E minimum (domestic and non-domestic) and surfaces the PROPOSED (not yet law) EPC C / 2030 uplift as an advisory only. Returns compliance, can-let, cost cap and penalties. Required: property_type, current_epc_band.
part_o_overheating(floor_area_m2, location_risk, glazing_area_m2, cross_ventilation, most_glazed_facade, provided_free_area_m2)- UK Approved Document O 2021 simplified-method overheating check for new residential: tests maximum glazing area (by orientation, risk zone, cross vs single aspect) and minimum free ventilation area. Returns pass/fail and points to CIBSE TM59 modelling if it fails. Indicative. Required: location_risk, most_glazed_facade, floor_area_m2, glazing_area_m2.
part_s_ev(works, dwellings, building_type, parking_spaces, covered_car_park)- UK Approved Document S 2021 electric-vehicle charge-point requirement calculator for new build and major renovation, residential and non-residential. Returns required charge points, cable routes (1-in-5 for non-residential), minimum power and the applicable cost caps/exemptions. Indicative. Required: building_type, works, parking_spaces.
roi_calculator(team_size, hourly_rate, manual_hours, software_cost, efficiency_gain_pct, implementation_time_months)- Engineering ROI calculator. Returns current manual cost, annual saving, net benefit, ROI %, payback months, 3-year NPV and a verdict. Required: team_size, hourly_rate, manual_hours, efficiency_gain_pct, implementation_time_months.
sap_sbem_precheck(sap_rating, floor_area_m2, annual_energy_kwh)- UK SAP 10.3 / SBEM EPC precheck. Maps a known SAP rating (1-100) to its EPC band, and/or computes annual CO2 and primary energy from fuel consumption using validated SAP 10 fuel factors. The official EPC band is cost-based and needs a full SAP/RdSAP assessment.
thermal_load(it_load_kw, redundancy, lighting_kw, cooling_type, room_area_m2, ambient_temp_c, ups_efficiency_pct)- Thermal Load Estimator for data centres / critical facilities. Returns total heat load, cooling capacity, units, airflow, chiller size, PUE estimate, power density, and a CRAC/CRAH/DLC/immersion comparison. Required: it_load_kw, ups_efficiency_pct, room_area_m2, cooling_type, redundancy, ambient_temp_c.
uae_climate_ghg(gas_m3, emirate, gas_kwh, electricity_kwh)- UAE Scope 1 + Scope 2 GHG estimate from electricity and gas use, with emirate-specific grid emission factors (Dubai/Abu Dhabi/national) and the Federal Decree-Law No. 11 of 2024 mandatory-reporting context. Grid factors carry base-year/confidence caveats. Required: emirate, electricity_kwh.
uk_planning_checker(listed, location, proposal, article_4, use_class, proposed_use, property_type, conservation_area, extension_depth_m, national_park_aonb)- UK permitted-development (GPDO 2015, England) rules engine for extensions, loft conversions and change of use. Returns a verdict (likely_pd / requires_permission / complex), applicable PD class, conditions and flags (listed building, Article 4, conservation area, AONB). Indicative, verify with the LPA. Required: property_type, proposal.
Last successful function declaration observed on . Source: https://api.novtriq.tech/mcp. We list what the server declared; we do not call any of these functions.
Endpoint status observed on . Source: https://api.novtriq.tech/mcp.
Signals
These are separate measurements of different things. They are deliberately not combined into one score, because a popularity number that mixes website traffic with saves and stars cannot be checked or acted on.
| Signal | Value | What it measures | Window | Observed | Source |
|---|---|---|---|---|---|
| Latest published version | 1.0.0 | Latest version string the maintainer published to the registry. | as of fetch | Model Context Protocol | |
| Registry record last updated | 2026-07-26 | When the registry record was last updated by its maintainer. | point in time | Model Context Protocol | |
| First listed in the MCP Registry | 2026-07-26 | Date this server was first published to the official MCP Registry. Not a usage or quality measure. | point in time | Model Context Protocol | |
| mcp tools declared | 27 tools | Number of functions the server itself declared when asked to list them. This is what the server offers an agent, not a measure of how well any of them work. | as of probe | api.novtriq.tech | |
| mcp endpoint status | ok | The server listed 27 functions when asked. | as of probe | api.novtriq.tech |
Where to get it
This record as data
Every field on this page, with its source and observation date, is in the catalog JSON. Fetch the whole kind at once instead of parsing this HTML.
GET /api/v1/entries/mcp_server.json